dc.description.abstractSteel and concrete composite systems are generally used as major structural components in multi-storey buildings. Composite construction in buildings is more popular with profiled steel sheeting (steel decking) since it serves as a working platform to support the construction loads and also as permanent formwork for concrete. To achieve large column free spans (in the range of 8m-12m), as often demanded for multi-storey office buildings, "steel and concrete composite floor trusses" may form economical solutions since they provide the facility to accommodate various service ducts within the structural zone. The concept of introducing a concrete filled steel tube (CFST), instead of the conventional open flanged steel section, as the top chord of these floor trusses has been discussed. However, the viability of this new concept should be ensured by experimental evidence on the longitudinal shear transfer capacity at the composite stage. This study discusses the experimental results of a series of push-off tests conducted on CFST embedded composite slab panels. The effect of providing different concrete top covers and effect of different concrete strengths have been investigated. With headed shear studs (two studs per sample, Configuration 3) 23%- 29% and 20%- 53% of increase in shear carrying capacity were achieved by increasing the concrete top cover from 20mm to 30mm and the concrete cube strength from grade 20 to grade 45 respectively. Composite slabs with CFSTs were 131% (only steel tube, Configuration 1) - 385% (steel tube with welded two steel strips, Configuration 2) higher than composite slabs with headed shear studs (two studs per sample). Then results of composite slabs with headed shear studs were compared with Eurocode-4 and it was at least 22% conservative. Keywords: composite slab, steel, concrete, concrete filled steel tubes, steel deckingen_US
dc.language.isoenen_US
dc.publisherUniversity of Moratuwaen_US
dc.subjectShear capacityen_US
dc.subjectconcrete filled steel tubesen_US
dc.subjectcomposite deck slabsen_US
dc.titleShear capacity of composite deck slabs with concrete filled steel tubesen_US
dc.typeThesisen_US
Appears in Collections:Book/Thesis
Book/Thesis
Books/Theses

Files in This Item:
File Description SizeFormat 
Pre-text.pdf3.51 MBAdobe PDFView/Open
Chapter1.pdf1.56 MBAdobe PDFView/Open
Chapter2.pdf2.58 MBAdobe PDFView/Open
Chapter3.pdf1.12 MBAdobe PDFView/Open
Chapter4.pdf4.05 MBAdobe PDFView/Open
Chapter5.pdf1.87 MBAdobe PDFView/Open
Chapter6.pdf385.4 kBAdobe PDFView/Open
Post-text.pdf31.97 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.